Buyer's Guide · Part 2 of 6
Choosing the right gas geyser size: Start with how you use hot water
The litre rating on a gas geyser is not the size of a storage tank. It describes the approximate hot-water flow the appliance can deliver per minute under specified conditions. Choosing correctly starts with understanding simultaneous demand.
Litres per minute, not litres stored
An electric storage geyser holds a volume of heated water in a tank. An instantaneous gas geyser works differently: it heats water as it flows through the unit. Its capacity is therefore commonly expressed in litres per minute (L/min). A 16 L/min model is designed to deliver a flow of heated water at a specified temperature rise and under the operating conditions stated by its manufacturer. It does not store 16 litres of hot water.
This distinction matters because a model’s stated flow rate is not a promise that it will deliver that flow at every possible temperature, inlet-water temperature or site condition. The colder the incoming water, the more energy is required to raise it to the same outlet temperature. Always compare a model’s technical information and temperature-rise performance, not just the large litre number on the box.
The question that matters most: what runs at the same time?
A common mistake is to choose a geyser based only on the number of people in the home or the number of bathrooms. Those details help describe the household, but they do not tell you how much hot water is needed at one moment.
Imagine a home with two bathrooms. If the family uses one shower at a time, its peak demand may be modest. If two showers regularly run together, the geyser must meet the combined demand. Add a kitchen tap or bath filler and the total can increase further.
Start by listing the hot-water outlets you genuinely expect to use simultaneously. Do not add every tap in the house unless you intend to run them together. Equally, do not ignore a second shower simply because it is only used at busy times. The system needs to cope with the household’s realistic peak use.
Measure flow instead of guessing
A simple bucket test can help you understand the flow available at an outlet. It is a useful screening exercise, not a substitute for a proper site assessment or the manufacturer’s sizing guidance.
- Choose an outlet and place a measuring container or bucket beneath it. For a shower, collect the water safely without creating a slip hazard.
- Run the outlet at the flow setting you normally use, or at the setting you want the system to support.
- Collect the water for 30 seconds and measure the volume in litres.
- Multiply the collected litres by two to estimate litres per minute. For example, 5 litres collected in 30 seconds is approximately 10 L/min.
- Repeat for the other outlets you expect to use at the same time. Add those measured flows to estimate the combined demand.
For example, if two showers each use about 7 L/min, their combined demand is approximately 14 L/min. If a kitchen tap is also expected to run at the same time and uses 3 L/min, the combined demand would be around 17 L/min. This is an illustration of the calculation, not a recommendation for a particular model.
Measure the outlets under realistic conditions. A tap opened fully may use more water than the setting your family normally uses. If you are renovating, changing shower heads or adding another bathroom, size for the planned future arrangement rather than the current one.
Why pressure and plumbing matter
Flow rate and water pressure are related, but they are not interchangeable. A home can have a reasonable static pressure reading yet still struggle to deliver enough flow when several outlets are open. Pipe diameter, pipe length, restrictions, filters, valves, pumps and the condition of the plumbing can all influence the water reaching the geyser and the outlets.
Some gas geysers are designed for particular pressure ranges or low-pressure systems. Others are intended for higher-pressure domestic plumbing. A model that is suitable for one water system may not be suitable for another. The installer should confirm that the home’s supply pressure and flow fall within the appliance’s specified operating range.
Single-outlet and multi-outlet use
Not all gas geysers respond to changing demand in the same way. Some simpler models are intended for one outlet at a time and may require the user to adjust the temperature manually. Other models use electronic temperature control to maintain a more consistent outlet temperature as demand changes, and may be designed to serve more than one outlet at once.
The important point is to understand the model’s actual capability. A higher litre rating alone does not guarantee that a geyser is designed for simultaneous use. Check whether the manufacturer describes the appliance as single-use or multi-use, whether it can modulate its output, and what flow range it supports.
Temperature rise changes the available flow
A geyser has to transfer heat into the water. The amount of water it can heat depends partly on how much the temperature needs to rise. In winter, incoming water may be colder than in summer. If you want a higher outlet temperature, the appliance must provide a greater temperature rise. Under some conditions, the maximum available flow may therefore be lower than the headline rating.
This is one reason to avoid selecting a model right at the edge of your estimated demand without checking its technical specifications. A qualified supplier or installer can help interpret the manufacturer’s flow and temperature-rise charts for your expected conditions.
A practical sizing checklist
- How many showers or hot-water outlets do you expect to run together?
- What is the measured or estimated flow of each of those outlets?
- Are there large rainfall shower heads, bath fillers or high-flow mixers?
- Will the household’s usage change in the next few years?
- What water pressure and flow are available at the property?
- Does the model support simultaneous use, or is it designed for one outlet at a time?
- What flow can it deliver at the temperature rise relevant to your area and season?
Do not buy by the number alone
A larger geyser is not automatically the best choice. It may cost more, require different gas supply arrangements or have operating requirements that do not suit the property. A smaller model may be perfectly adequate for a household that uses one outlet at a time. The right size is the one that meets the household’s realistic demand while remaining compatible with the water supply and installation.
Use your measurements as a starting point, then confirm the selection against the manufacturer’s specifications and the installer’s assessment. That gives you a much stronger basis for comparing products than choosing by household size alone.
Next: once you understand the capacity you need, compare the different types of gas geyser and the features that affect how they operate.